{"product_id":"roland-s-0816-digital-snake-front-of-house-unit","title":"Roland S-0816 Digital Snake Front of House Unit","description":"\u003cp\u003e\u003cspan style=\"line-height: 1.3em;\"\u003eBuy Roland S-0816 Digital Snake Front of House Unit online in India  - India's music equipment superstore.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRoland S-0816 Digital Snake Front of House Unit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S-1608 and S-0816 Digital Snake are compact versions of the popular S-4000 Digital Snake System. Easy to use and quick to install, the S-1608 Digital Snake System is a small format audio snake solution that offers the highest quality audio signal available in a portable snake system. The S-1608 Digital Snake system is ideal for bands, corporate A\/V events, seminars, rental and staging houses, Houses of Worship and broadcasters that need the best possible sound quality from their audio without the high frequency losses and bulk of an analog snake.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAC Technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe REAC (\u003ca data-lwsa=\"eyJhdXRvbGluayI6dHJ1ZSwiYXV0b19pZCI6IjI1NzY2In0=\" href=\"https:\/\/www.bajaao.com\/collections\/roland\" target=\"_blank\" rel=\"noopener\" title=\"Roland\"\u003eRoland\u003c\/a\u003e Ethernet Audio Communication) protocol is an industry proven, low latency, high quality 24 bit\/ 96 kHz audio transport protocol used by the S-1608 and S-0816. The REAC protocol allows the Digital Snake's signal to be \"split\" to as many positions as required such as monitor, broadcast and recording splits using the S-4000D or any standard gigabit Ethernet switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Resolution Sound Quality\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy placing high quality mic-pres on stage, the sound is amplified and converted at the closest point to the sound source, providing the best possible quality audio. The mic preamps can be controlled using the S-4000R or the free PC\/Mac RCS software. By using Cat5e cable instead of large multi-core copper cable, the S-1608 Digital Snake system is immune to the \"hums and buzzes\" caused by electrical noise and ground issues and the high frequency losses inherent in analog snakes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Expansion for the S-4000 Digital Snake System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S-1608 Digital Snake System can be used to easily expand the channel count of an S-4000 32 x 8 Digital Snake System to 48 x 16. Mix and match S-4000 and S-1608 Digital Snake Systems for customizable rental and installation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCreate Multiple Stage Configurations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse multiple S-1608 Digital Snake Systems to create flexible stage configurations such as Left, Right and Center snake positions. Simply run Cat5e cables to the Front of House console for easy cable management on stage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSplit the S-1608 Digital Snake Easily for Monitoring, Broadcasting, or Recoding Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the S-1608 Digital Snake system, the source audio can be digitally split using the S-4000D or any standard Ethernet switch. These lossless digital splits can be routed over CAT5 cable to a monitoring console or a broadcast truck for recording.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRoland S-0816 Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumber of Channels - 8 in 16 out\u003c\/li\u003e\n\u003cli\u003eAD Conversion - Sample Rate: 96.0 kHz, Signal Processing: 24 bits\u003c\/li\u003e\n\u003cli\u003eDA Conversion - Sample Rate: 96.0 kHz, Signal Processing: 24 bits\u003c\/li\u003e\n\u003cli\u003eFrequency Response -  -2 dB \/ +0 dB (@ +4 dBu, 20 Hz to 20 kHz)\u003c\/li\u003e\n\u003cli\u003eTotal Harmonic Distortion + Noise - 0.05 % or less (Pad: On, Input Gain: +4 dBu, 22 to 20000 Hz)\u003c\/li\u003e\n\u003cli\u003eDynamic Range - 110 dB\u003c\/li\u003e\n\u003cli\u003eNominal Input Level - -65 to -10 dBu (PAD: Off); -45 to +10 dBu (PAD: On) (1 dB step, Max. +28 dBu)\u003c\/li\u003e\n\u003cli\u003ePAD - 20 dB On\/Off\u003c\/li\u003e\n\u003cli\u003eInput Impedance - 14 k ohms\u003c\/li\u003e\n\u003cli\u003eNominal Output Level - +4 dBu, Max. +22 dBu\u003c\/li\u003e\n\u003cli\u003eOutput Impedance - 600 ohms\u003c\/li\u003e\n\u003cli\u003eRecommended Load Impedance - 10 k ohms or greater\u003c\/li\u003e\n\u003cli\u003eResidual Noise Level (IHF-A, typ.) - -80 dBu or less\u003c\/li\u003e\n\u003cli\u003eEquivalent Input Noise Level (E.I.N.) - -128 dB\u003c\/li\u003e\n\u003cli\u003eNetwork Latency - 375 microseconds when using REAC cable only (AD - REAC - DA Latency: about 1.2 ms)\u003c\/li\u003e\n\u003cli\u003ePower Supply - AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003ePhantom Power - +48 V \/ 14 mA (each input, remote controlled)\u003c\/li\u003e\n\u003cli\u003eDimensions - 399.0 (W) x 135.0 (D) x 177.0 (H) mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 8 (XLR type, balanced, phantom power)\u003c\/li\u003e\n\u003cli\u003eOutput: 16 (XLR type, balanced)\u003c\/li\u003e\n\u003cli\u003eREAC Connector: 1 (RJ-45 EtherCon type)\u003c\/li\u003e\n\u003cli\u003eRemote Connector: 1 (RS-232C, DB-9 type)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators\u003cspan style=\"white-space: pre;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOWER Indicator x 1\u003c\/li\u003e\n\u003cli\u003eREAC Indicator x 1\u003c\/li\u003e\n\u003cli\u003eREMOTE Indicator x 1\u003c\/li\u003e\n\u003cli\u003eMUTE ALL OUTPUTS Indicator x 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperation Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e- 0 to +40 degrees centigrade\u003c\/li\u003e\n\u003cli\u003e+32 to +104 degrees Fahrenheit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Cord x 1\u003c\/li\u003e\n\u003cli\u003eREAC Connector Covers x 1\u003c\/li\u003e\n\u003cli\u003eFerrite Core x 1\u003c\/li\u003e\n\u003cli\u003eRubber Foot x 4\u003c\/li\u003e\n\u003cli\u003eRack Mount Kit x 1\u003c\/li\u003e\n\u003cli\u003eOwner´s Manual\u003c\/li\u003e\n\u003cli\u003eOptions - Cat5e Ethernet Crossover Cable with Neutrik(R) EtherCon(R) Plug: SC-W100S (100 m).\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eMade in China\u003c\/strong\u003e\u003c\/p\u003e","brand":"Roland","offers":[{"title":"Default Title","offer_id":1004429439,"sku":"ROLANDS0816","price":115900.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0657\/6821\/files\/roland-signal-processors-roland-s-0816-digital-snake-front-of-house-unit-1252921179.jpeg?v=1689057949","url":"https:\/\/www.bajaao.com\/products\/roland-s-0816-digital-snake-front-of-house-unit","provider":"BAJAAO.COM","version":"1.0","type":"link"}